Detailed hydraulic and electrical diagrams included in installation manual.
INSTALLATION SCHEMATICS
A - 1 CIRCUIT (UNDERFLOOR HEATING OR RADIATORS) + INTEGRATED DHW
1 Outdoor unit and floor supports(1)
2 Refrigeration links(1)
3 Indoor unit
4 Modulating thermostat (except with dynamic radiator)(1)
5 Buffer tank(2)
(1) Optional (2) Depending on the emitter type and quantity of water in the heating circuit, it may be necessary to install a buffer tank.
B - 2 CIRCUITS (UNDERFLOOR HEATING OR RADIATORS) + INTEGRATED DHW
1 Outdoor unit and floor supports(1)
2 Refrigeration links(1)
3 Indoor unit
4 Modulating thermostat (except with dynamic radiator)(1)
5 Buffer tank(2)
6 2nd circuit
(1) Optional (2) Depending on the emitter type and quantity of water in the heating circuit, it may be necessary to install a buffer tank.
1
3
5
4
4
4
CAR
GS
SP
PC
CAR
D
MT
Rdyn*
R
1
5
3
4
4
4D
Rdyn*
R
GS
CAR
CAR SP
PC
Circuit 1 (direct)
Circuit 2 (mélangé)
MT
MT SDpM
CCM
6
53