INSTALLATION SCHEMATICS
A - 1 HEATING CIRCUIT
1 Outdoor unit and floor supports(1)
2 Refrigeration links(1)
3 Indoor unit
4 Modulating thermostat(1)
5 Magnetic sludge filter(1)
6 Buffer tank(2)
7 DHW boiler
MH
Kit ECS
AE
Dec
Ssa
OU
R
SA*
OU
Rdyn*
PC
SP
1 2
4
4
4
3
7
6
5
SA
SA
VD
CC
(1) Optional (2) Depending on the emitter type and quantity of water in the heating circuit, it may be necessary to install a buffer tank.
B - 2 HEATING CIRCUITS
1 Outdoor unit and floor supports(1)
2 Refrigeration links(1)
3 Indoor unit
4 Modulating thermostat(1)
5 Magnetic sludge filter(1)
6 Buffer tank(2)
7 2-circuit kit(1)
MH
OU
R
SA*
OU
Rdyn*
PC
Circuit 2 (mélangé)
Circuit 1 (direct)
SP
1 2
4
4
4
3
SA
SA
CC
CCM
K2c
SDpMB
Dec
5
VM
CAR 6
7
(1) Optional (2) Depending on the emitter type and quantity of water in the heating circuit, it may be necessary to install a buffer tank.
Detailed hydraulic and electrical diagrams included in installation manual.