Your browser is not up to date and is not able to run this publication.

INSTALLATION DIMENSIONS (mm)

Er P

TECHNICAL CHARACTERISTICS AND PERFORMANCE DESCRIPTION UNIT LORIA 6004 R32 LORIA 6006 R32 LORIA 6008 R32 LORIA 6010 R32

Refrigerant R32 R32 R32 R32 TECHNICAL CHARACTERISTICS AND PERFORMANCE Energy class - heating (35°C/55°C) package - A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ Thermal output (35 °C / 55 °C) kW 5 / 5 6 / 5 7 / 6 9 / 9 Annual energy consumption - heating (35 °C / 55 °C) kWh 2418 / 3018 2614 / 3307 2901 / 3751 3796 / 5014 Seasonal energy efficiency - heating (35° / 55°) without an outdoor sensor % 182 / 128 192 / 134 187 / 136 188 / 141 Seasonal energy efficiency - heating (35° / 55°) with an outdoor sensor % 184 / 130 190 / 132 185 / 134 186 / 139

Sound power (indoor / outdoor) dB(A) 40 / 57 40 / 57 40 / 60 40 / 62 GENERAL CHARACTERISTICS SCOP (35°/55°) 4.61 / 3.29 4.82 / 3.37 4.70 / 3.41 4.73 / 3.54 Heating capacity +7°C/+35°C - UH kW 4.60 5.60 7.50 9.80 COP +7°C/+35°C - UH 4.83 4.81 4.52 4.53 Heating capacity -7°C/+35°C - UH kW 4.50 5.30 5.90 9.20 COP -7°C/+35°C - UH 2.94 2.73 2.72 2.63 Heating capacity +7°C/+55°C - Rad kW 4.50 5.60 7.20 9.50 COP +7°C/+55°C - Rad 2.72 2.77 2.77 2.85 Heating capacity -7°C/+55°C - Rad kW 3.90 4.25 5.30 8.00 COP -7 °C/+55 °C - Rad 1.91 1.95 1.96 2.01 Electrical backup heating capacity kW 3 3 3 3 INDOOR UNIT Noise level(1) dB(A) 32 32 32 32 Unladen weight/filled weight kg 42 / 46 42 / 46 42 / 46 42 / 46 HYDRAULIC CHARACTERISTICS Vessel expansion capacity l 8 8 8 8 Heating circuit input and output diameters (male thread) pouce 1 1 1 1 Recommended operating range min/max - hot mode °C -20 / +35 -20 / +35 -20 / +35 -20 / +35 ELECTRICAL CONNECTION Power supply 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz Power consumption on standby W 5 5 5 5 Circuit breaker rating for heat pump booster heaters curve C A 16 16 16 16 Heat pump booster heater power cables mm2 3G 1.5 3G 1.5 3G 1.5 3G 1.5 FUJITSU OUTDOOR UNIT Noise level(2) dB(A) 35 35 38 40 Weight in operation kg 39 39 42 62 REFRIGERANT CHARACTERISTICS Gas diameter pouce 1/2 1/2 1/2 5/8 Liquid diameter pouce 1/4 1/4 1/4 3/8 Refrigerant factory load HFC R32 g 970 970 1020 1630 Quantity of fluid in tonnes of CO2-eq t 1 1 1 1 Min/max length m 3 / 30 3 / 30 3 / 30 3 / 30 Max difference in height m 20 20 20 20 Max length with no additional load m 15 15 15 20 Masse de gaz à rajouter par m supplémentaire g 25 25 25 20 RACCORDEMENTS ÉLECTRIQUES Alimentation 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz Standby power W 38 38 38 38 Max intensity (excluding booster heaters) A 13 13 18 19 Circuit breaker rating C curve A 16 16 20 32 Power cable, outdoor module mm2 3G1.5 3G1.5 3G2.5 3G 4 or 6 Cables connecting the outdoor and indoor modules mm2 4G1.5 4G1.5 4G1.5 4G1.5 (1) Acoustic pressure at 1m from HP, 1,5 m from the ground, open field, directivity 2. (2) Acoustic pressure at 5m from HP, 1,5 m from the ground, open field, directivity 2.

Indoor hydraulic module 450

92 3

65 161 343

93 5

84 1

80 3

60 60

275 105

Front view Side view

Bottom view

Front viewSide view

886

33

63 2

6325

353 180

33

63 2

12 0 18 4

88

580

33 0

Air

Outdoor Inverter unit Loria R32 5 and 6

Bottom view

Side view Front view

907

3

71 6

90

600

33 0

Air

07349

353 194

3

6

11 9 18

4

Outdoor Inverter unit Loria R32 8

Outdoor Inverter unit Loria R32 10

Bottom view

Side view Front view

39 1

650

35 5

Air

365

99 6

9405

48

Heat pumps & renewable energy solutions 2022 - AtlanticHeat pumps & renewable energy solutions 2022 - AtlanticHeat pumps & renewable energy solutions 2022 - AtlanticHeat pumps & renewable energy solutions 2022 - AtlanticHeat pumps & renewable energy solutions 2022 - AtlanticHeat pumps & renewable energy solutions 2022 - AtlanticHeat pumps & renewable energy solutions 2022 - AtlanticHeat pumps & renewable energy solutions 2022 - AtlanticHeat pumps & renewable energy solutions 2022 - AtlanticHeat pumps & renewable energy solutions 2022 - AtlanticHeat pumps & renewable energy solutions 2022 - AtlanticHeat pumps & renewable energy solutions 2022 - AtlanticAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range presentationAlfea range accessoriesAlfea range accessoriesAlfea range accessoriesLoria range presentationLoria range presentationLoria range presentationLoria range presentationLoria range presentationLoria range presentationLoria range presentationLoria range presentationLoria range presentationLoria range accessoriesLoria range accessoriesWall-InWall-InAtlantic Geolia range presentationAtlantic Geolia range presentationAtlantic Geolia range presentationAtlantic Geolia range presentationPanama AccessPanama AccessPanama AccessPanama AccessPanama Access
Powered by Fluidbook