INSTALLATION DIMENSIONS (mm) Indoor hydraulic module
91 75
52 15
23 318
06 58
5 5 525
88 12 18 3
23 9
Top view
590
17 77
17 10
17 50
17 68
Front view
Bottom view
Front viewSide view
86
33 0
63 2
86325
353 180
33
63 2
12 0 18 4
88
580
33 0
Air
Outdoor Inverter unit Loria Duo R32 3, 4 and 6
Bottom view
Side view Front view
907
3
71 6
90
600
33 0
Air
07349
353 194
3
6
11 9 18
4
Outdoor Inverter unit Loria Duo R32 8
Outdoor Inverter unit Loria Duo R32 10
Bottom view
Side view Front view
39 1
650
35 5
Air
365
99 6
9405
TECHNICAL CHARACTERISTICS AND PERFORMANCE DESCRIPTION UNIT LORIA DUO 6003 R32
LORIA DUO 6004 R32
LORIA DUO 6006 R32
LORIA DUO 6008 R32
LORIA DUO 6010 R32
Refrigerant R32 R32 R32 R32 R32 CHARACTERISTICS AND HEATING PERFORMANCE Energy class - heating (35°C/55°C) package - A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ A+++ / A++ Thermal output (35 °C / 55 °C) kW 4 / 4 5 / 5 6 / 5 7 / 6 9 / 9 Annual energy consumption - heating (35 °C / 55 °C) kWh 930 / 1313 2418 / 3018 2614 / 3307 2901 / 3751 3796 / 5014 Seasonal energy efficiency - heating (35° / 55°) without an outdoor sensor % 181 / 126 182 / 128 190 / 132 185 / 134 186 / 139 Seasonal energy efficiency - heating (35° / 55°) with an outdoor sensor % 183 / 128 184 / 130 192 / 134 187 / 136 188 / 141 Sound power (indoor/outdoor) dB(A) 40 / 57 40 / 57 40 / 57 40 / 60 40 / 62 DHW CHARACTERISTICS AND PERFORMANCE Draw-off profile - DHW - L L L L L Energy class - DHW - A+ A+ A+ A+ A+ Annual energy consumption in kWh - DHW kWh 777 777 777 777 777 Seasonal energy efficiency - DHW % 132 132 132 132 132 GENERAL CHARACTERISTICS SCOP (35°/55°) 4.60 / 3 22 4.61 / 3.29 4.82 / 3.37 4.7 / 3.41 4.73 / 3.54 Heating capacity +7 °C/+35 °C - UH kW 3.30 4.60 5.60 7.50 9.80 COP +7 °C/+35 °C - PC 2.20 4.83 4.81 4.52 4.53 Heating capacity -7 °C/+35 °C - UH kW 3.50 4.50 5.30 5.90 9 20 COP -7 °C/+35 °C - PC 3.03 2.94 2.73 2.72 2.63 Heating capacity +7 °C/+55 °C - Rad kW 3.10 4.50 5.60 7.20 9.50 COP +7 °C/+55 °C - Rad 2.55 2.72 2.77 2.77 2.85 Heating capacity -7 °C/+55 °C - Rad kW 3.30 3.90 4.25 5.30 8.00 COP -7 °C/+55 °C - Rad 1.77 1.91 1.95 1.96 2.01 Electrical backup heater heating capacity kW 3 3 3 3 3 INDOOR UNIT Noise level(1) dB(A) 32 32 32 32 32 Unladen weight/filled weight kg 135 / 330 135 / 330 135 / 330 135 / 330 135 / 330 HYDRAULIC CHARACTERISTICS Vessel expansion capacity l 8 8 8 8 8 DHW tank capacity l 190 190 190 190 190 DHW electrical backup heating capacity kW 1.60 1.60 1.60 1.60 1.60 Materials DHW tank Enamelled steel Warming-up time in compliance with EN16147 h/mn 1h36 1h36 1h36 1h36 1h36 Reference temperature in compliance with EN16147 °C 52.5 52.5 52.5 52.5 52.5 DHW COP in compliance with EN16147 - 3.26 3.26 3.26 3.26 3 26 Max usable volume of hot water in compliance with EN16147 L 243 243 243 243 243 Reserve power in compliance with EN16147 W 31 31 31 31 31 Heating circuit input and output diameters (male thread) pouce 1 1 1 1 1 Recommended operating range min/max - hot mode °C -20 / +35 -20 / +35 -20 / +35 -20 / +35 -20 / +35 ELECTRICAL CONNECTION Power supply 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz Power consumption on standby W 5 5 5 5 5 Circuit breaker rating for heat pump booster heaters curve C A 16 16 16 16 16 Heat pump booster heater power cables mm2 3G 1.5 3G 1.5 3G 1.5 3G 1.5 3G 1.5 FUJITSU OUTDOOR UNIT Noise level(2) dB(A) 35 35 35 38 40 Weight in operation kg 39 39 39 42 62 REFRIGERANT CHARACTERISTICS Gas diameter pouce 1 / 2 1 / 2 1 / 2 1 / 2 5 / 8 Liquid diameter pouce 1 / 4 1 / 4 1 / 4 1 / 4 3 / 8 Refrigerant factory load HFC R32 g 970 970 970 1020 1630 Quantity of fluid in tonnes of CO2-eq t 1 1 1 1 1 Min/max length m 3 / 30 3 / 30 3 / 30 3 / 30 3 / 30 Max difference in height m 20 20 20 20 20 Max length<1} with no additional load m 15 15 15 15 20 Quantity of gas to be added per additional m g 25 25 25 25 20 ELECTRICAL CONNECTIONS Power supply 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz Standby consumption (Average power consumed by pump) W 38 38 38 38 38 Max intensity (excluding booster heaters) A 13 13 13 18 19 Circuit breaker rating C curve A 16 16 16 20 32 Power cable, outdoor module mm2 3G1.5 3G1.5 3G1.5 3G2.5 3G 4 or 6 Cables connecting the outdoor and indoor modules mm2 4G1.5 4G1.5 4G1.5 4G1.5 4G1.5 (1) Acoustic pressure at 5m from HP, 5 m from the ground, open field, directivity 2. (2) Acoustic pressure at 5m from HP, 1,5 m from the ground, open field, directivity 2.
Er P
Er P
52